Installation Instructions for 34HW–35HW IDH Max Mortise Locks
BEST ACCESS SYSTEMS
Indianapolis, Indiana
15
Installation Instructions for 34HW–35HW IDH Max Mortise Locks
Completing the installation at the door
16 Install core (EEL and EEU only)
1 Insert the control key into the core and rotate the key
15 degrees to the right.
2 With the control key in the core, insert the core into
the cylinder.
3 Rotate the control key 15 degrees to the left and
withdraw the key.
Caution: The control key can be used to remove
cores and to access doors. Provide adequate
security for the control key.
17 Install access door
1 Making sure that the access door does not pinch
any wires, insert the tabs of the access door into its
mating slots and swing the door closed.
2 Use a T15 TORX bit driver to secure the access door
with the security screw. Tighten firmly.
Figure 16 Installing the core
Control key
Core
Inside of door
Figure 17 Installing the access door
Security scre
w
Tabs
Seitenansicht 178