
Installation Instructions for 34HW–35HW IDH Max Mortise Locks
BEST ACCESS SYSTEMS
Indianapolis, Indiana
17
Installation Instructions for 34HW–35HW IDH Max Mortise Locks
Installing the panel interface module
19 Install lock power supply (optional)
If you are providing a separate power supply for the
lock, instead of providing power via the panel
interface module, connect the two power field wires
(run from the wire transfer hinge) to the power supply.
Make sure power (12 volts DC) and ground are
connected properly.
Follow the instructions provided by the power supply
manufacturer. Do not plug in the power supply yet.
Note: For specifications for the power supply, see
Components checklist, on page 2.
20 Mount panel interface module
Peel the paper off the adhesive tape affixed to the
back of the panel rail and press the panel rail into
position.
Note: Mount the panel interface module in the
enclosure with the access control panel/reader interface,
if possible.
Figure 20 Mounting the panel interface module
Adhesive
tape
Kommentare zu diesen Handbüchern