Installation and Conguration25
Task 5: Dene Ofine Access Panels
Although B.A.S.I.S. Locks are ofine (stand-alone) locks and are not managed by access control panels,
you must dene Virtual Access Panel settings for the locks. Using the access panel concept allows the
programming of guest locks to follow the same conventions as B.A.S.I.S. online products. Up to 64 locks
(called readers in B.A.S.I.S.) can share the same panel conguration. However, these readers must all:
• be managed by the same Server or Workstation
• share the same password
• be located in the same time zone
• use the same daylight saving time setting.
Note The default password is ‘BEST.’ Care should be given to faithfully document any changes to
this password since the password cannot be viewed from anywhere in the B.A.S.I.S. application
software.
Perform the following steps:
1 From System Administration, click Access Control > Access Panels.
2 Click the Ofine Lock tab.
3 Click Add.
The Ofine Lock Access Panel window displays.