Installation and Conguration29
Dene Other Guest Reader Features
1 From System Administration, click Access Control > Readers and Doors.
2 Select the Reader that you want to dene. Make sure that the check mark is next to the reader to be
modied.
3 Click the Ofine tab.
4 Click Modify.
The Modify Ofine Reader window displays.
Figure 14 Dening the ofine reader
5 In the Chassis Type eld, select the chassis type that the lock/reader has.
Note The custom chassis type enables the modication of the chassis volume. The chassis volume is a
value used by engineers that relates to the number of turns of the motor that is required to unlock
the lock. Only use the custom chassis type at the direction of a technical support engineer or
specic instructions enclosed with the lock.
6 In the Cardholders eld, select the total number of cardholders that will need to access the lock/reader.
7 In the Look Ahead section, select the look ahead offset and range. Normally for B.A.S.I.S. G locks, the
offset is set to 1 and the range to 3.
8 The Guest Parameters section, select whether the reader will be a Common door.
Make sure that
the correct reader
is selected when
selecting ofine
features.
The common door
feature allows
duplication of a
badge range
between locks.
The number of
events is
automatically
calculated based
on the amount of
lock memory and
the number of
cardholders
allocated.
Kommentare zu diesen Handbüchern