Seitenansicht 176
Installation Instructions for 34HW–35HW IDH Max Mortise Locks
BEST ACCESS SYSTEMS
Indianapolis, Indiana
13
Installation Instructions for 34HW–35HW IDH Max Mortise Locks
Completing the installation at the door
14 Secure through-bolt trim and complete
connections
1 Position the inside and outside trim onto the door.
2 Making sure that the trim does not pinch the
wires, secure the trim to the door—but do not
tighten. Use the combination mounting screw at the
top trim hole and the standard mounting screw at the
bottom trim hole.
Caution: When routing the solenoid and sensor
wire harness, the sensor wires, and the solenoid
wires, make sure the wires are not routed across
any sharp edges or over any surface that could
damage their sleeving or wire insulation.
3 Make the solenoid connection and three sensor
connections, and place the wires into the inside trim.
Caution: When making the sensor connections
and solenoid connection, make sure:
there are no loose wire connections where the
wires are inserted into the connectors
the connectors are firmly mated.
Wire connection Color
No. of
wires
No. of
pins
Solenoid Yellow 2 3
RQE Brn/Org 2 3
Shorting connection Purple 2 2
Door status sensor White 2 2
Figure 14 Securing the through-bolt trim and
completing connections
Combination
mounting screw
Standard
mounting screw
Make these
connections.
Inside of door
Inside trim
Seitenansicht 176
1 2 ... 172 173 174 175 176 177 178 179 180 181 182 ... 227 228

Kommentare zu diesen Handbüchern

Keine Kommentare